Yes, you can install a maglock on many door types, but a compliant setup needs a maglock and armature plate, a correctly sized power supply with battery backup, a request-to-exit device and, on escape routes, fire alarm integration with a manual green box release. Before you drill anything, work through the checklist below to confirm your door and frame suit the job, or book a professional survey if the door sits on an escape route.
TL;DR:
- A maglock installation requires a matching armature plate, a properly rated power supply with battery backup, and a request-to-exit device for reliable operation.
- For escape route doors, fire alarm integration and a manual green box release are mandatory, with additional coordination needed for fire safety compliance.
- Bracket selection and precise alignment are critical; incorrect fitting or mismatched brackets can significantly weaken the lock’s holding force or cause misalignment issues.
- Continuous power supply sizing and wiring practices, including proper cable routing and labeling, are essential to prevent faults and ensure system reliability.
- Hiring a professional installer is recommended for complex setups, fire alarm integration, or if the door sits on an escape route, to ensure compliance and safe operation.
A maglock installation has more moving parts than the lock itself. Before ordering anything, confirm the door type, the escape status of the route and whether you have the tools to do the mechanical and electrical work properly.
You will typically need:
For tools, you will want a drill with masonry and metal bits sized to the manufacturer’s quick-install guide, spade bits for cable runs through timber frames, a torque driver for the tamper-resistant fixings most maglocks specify, and a stud finder or frame scanner if you are working on a hollow metal or timber door frame.
Before buying anything, check whether the door sits on an escape route. Irish guidance requires escape routes to remain unobstructed at all times, and a government consultation has proposed tighter rules for door fastenings on escape routes to keep them immediately available for use. If the door you are working on is part of an escape route, you will need fire alarm integration and a manual release. This usually means bringing in a fire alarm contractor and, in many cases, a building design professional.
Frame and door suitability matter as much as the lock’s rated force. Glass doors, narrow aluminium stiles and fire-rated timber doors each need a specific bracket kit rather than a generic drill-and-fix approach, and mismatching the bracket to the door is one of the most common causes of a weak or misaligned installation.
Pro Tip: Photograph the door, frame and existing hardware before you order parts. Bracket manufacturers often need those details to confirm the correct kit.
As a rule of thumb: if the door is a standard timber or hollow metal door not on an escape route, and you are comfortable with a drill, a multimeter and basic wiring, DIY installation is realistic. If the door sits on an escape route, involves glass or curtain walling, or needs fire alarm integration, hire a locksmith or access control installer with commissioning experience.
Mechanical installation is where most maglock problems start, usually from rushed measurements or the wrong bracket. Work through this sequence in order, and do not skip the alignment checks.
1. Measure and mark with the door closed. Close the door fully and mark the centreline of the frame header and the door leaf where the magnet and armature will sit. Working with the door closed avoids the common mistake of mounting the armature slightly out of true, which shows up later as a weak or uneven hold.
2. Choose the bracket for your door type. An inswing door usually needs a Z-bracket to offset the armature plate away from the frame; an outswing door often takes a simpler L-bracket. Narrow stile aluminium doors and glass doors need dedicated S-bracket or glass-clamp kits rather than a standard bracket, since there is no timber or metal substrate to drill into in the usual way; more details on aluminium door bracket options can be found on the Aluminium ajtók - A Te ablakod site.
3. Drill pilot holes for the maglock body. Using the hole spacing from the manufacturer’s quick-install guide, drill pilot holes into the frame header. Manufacturer documents such as the UA-Lock-Magnetic-270kg quick install guide specify exact hole sizes and spacing for the lock body and bracket, and following those dimensions is the difference between a lock that holds its rated force and one that does not.
4. Fix the maglock to the frame. Secure the lock body with the fixings supplied, tightened to a firm, even torque rather than as tight as the driver will go. Most maglocks use tamper-resistant screw heads on the exposed face; fit these last, once you have confirmed alignment, since they are harder to remove for adjustment.
5. Mount the armature plate on the door leaf. Position the armature so its face sits flush with the magnet when the door is closed. This is the step where a rubber washer matters most.
6. Fit the rubber washer and metal washer sandwich. Every maglock armature should sit on a rubber washer, with metal washers either side, between the plate and the door. This sandwich lets the armature rock and self-align with the magnet face when the door closes, rather than binding at one edge. Overtightening the armature fixings crushes this movement out and reduces the lock’s effective holding force, even if the lock itself is rated correctly.
7. Allow for rocking movement before final tightening. Close the door several times before fully tightening the armature screws, letting the plate settle against the magnet face on its own. Only then apply final torque, checking that the plate still has a small amount of give.
8. Fit tamper screws and cable covers. Once alignment is confirmed, fit any tamper-resistant fixings and cable covers, and route cable neatly into the frame or surface conduit.
Bracket-specific notes worth knowing before you start:
Before calling the mechanical work finished, run these checks:
Following the manufacturer’s own quick install guide for hole sizes and bracket dimensions matters more here than general advice, since drilling patterns vary between models even within the same holding-force class.
The magnet itself is only one part of a working system. Most installation problems trace back to underspecified power supplies, poorly placed REX devices or wiring mistakes rather than the lock body.
Maglocks are commonly rated at 12 VDC or 24 VDC, and the lock must run continuously at that voltage to hold its rated force, since a maglock draws power the entire time the door is secured. This continuous draw is different from an electric strike, which only draws power briefly during release, and it means your power supply has to be sized for sustained load, not just a momentary spike.
When selecting a power supply and battery backup:
Request-to-exit devices and door position switches need thought about placement, not just wiring. A REX push button should sit at a height and location that occupants naturally reach when leaving, and a motion-sensor REX needs its detection zone tested so it does not trigger from corridor traffic outside the door. Door position switches, usually magnetic reed contacts, should be fitted so they report an accurate open and closed state to the access controller, since a false “closed” signal will let the system re-lock a door that has not actually shut.
Integration with access controllers and alarm panels usually means wiring the maglock’s power-cut path through a relay controlled by the access panel, with the REX and door contact wired as separate monitored inputs. Where the door also needs fire alarm release, the alarm panel’s output typically feeds the same power-cut relay, cutting power to the lock independently of the access controller whenever the alarm activates.
A few wiring practices are worth following as standard:
Pro Tip: Test the REX and door contact wiring with a multimeter before connecting the lock itself. It is far easier to trace a wiring fault with the magnet disconnected.
Any maglock fitted on an escape route needs more than a REX button. Irish guidance treats a maglock on an escape route as a “Special Locking Arrangement,” which must release automatically on fire alarm activation and include a manual override.
A government consultation on fire safety and escape routes proposes that escape routes remain unobstructed and that certain fastenings be prohibited unless they allow immediate opening from inside. In practice, this means a maglock cannot be the only thing standing between an occupant and an open escape route unless it is wired to release the moment the fire alarm activates.
Official guidance on door fastenings for doors on escape routes lists maglocks as an acceptable option only when they are interfaced with the fire alarm system and fitted with a manual “green box” emergency release, and it specifies that this arrangement should be specified by a qualified building design professional rather than decided on site.
Before fitting a maglock on any escape route:
Technical Guidance Document B on fire safety is the other reference point worth consulting when assessing door fastenings on escape routes, alongside the appendix guidance above. Local approval is not optional on these doors: a maglock that looks correctly wired but lacks the fire alarm interface and green box release will fail an inspection regardless of how well it is mounted.
A maglock is not finished once it is mounted and wired. Commissioning is the stage that catches faults before occupants do, and it should be documented, not just performed.
1. Verify electrical basics. Measure voltage at the lock terminals with a multimeter to confirm it matches the rated voltage, check continuity on every wired connection, and confirm the battery backup takes over cleanly when mains power is disconnected.
2. Test the REX device. Trigger the REX button or sensor and confirm the lock releases within its expected delay and re-locks correctly afterwards.
3. Simulate the fire alarm release. With a responsible fire safety officer or building manager present, trigger the fire alarm and confirm the maglock releases immediately and stays released until the alarm is reset.
4. Test the green box manual release. Operate the manual release and confirm it cuts power to the lock directly, independent of the access controller or alarm panel.
5. Confirm door position reporting. Open and close the door several times and check the access controller logs accurate open and closed states each time.
6. Run a mechanical endurance check. Open and close the door repeatedly under normal use conditions, checking that the armature stays aligned and the lock continues to hold at full force.
For handover, produce a short commissioning record covering the voltage and continuity readings, the fire alarm simulation result with the officer’s name and date, and the battery backup test outcome. Keep this with the building’s fire safety file alongside any sign-off from the design professional who approved the escape-route arrangement.

Pro Tip: Set a maintenance reminder for six to twelve months out to retest the battery backup and REX response time, since battery capacity and sensor sensitivity both drift over time.
Most maglock faults after installation fall into a small number of categories, and most can be diagnosed with a multimeter before you call anyone out.
If a maglock does not release, start by confirming that power is actually being cut to the lock terminals when the REX or access controller is triggered. A maglock is fail-safe by design, meaning it should unlock the instant power is removed, so a lock that stays locked almost always points to a fault in the power-cut path rather than the magnet itself. Check the relay and controller output before assuming the lock has failed.
Misalignment problems usually trace back to the same cause: the armature was tightened before it had a chance to self-align, or the wrong bracket was fitted for the door’s swing direction. Loosening the armature screws, letting the door close and settle a few times, then retightening evenly often restores full holding force without swapping any parts.
Sticky locks are worth testing properly rather than guessing. Disconnect power, wait a moment, then check whether the armature separates cleanly from the magnet by hand. If it resists separation, residual magnetism from a suppression diode or a damaged magnet coil is the likely cause.
Typical Irish call-out and installation pricing reflects how much labour time these diagnostics take on site, since tracing a wiring fault through a frame can take longer than the original installation.
If you have checked power, relays and the armature sandwich and the fault persists, or if the door sits on an escape route, stop and call a qualified installer or electrician rather than continuing to test. Faults on fire-alarm-integrated systems in particular should not be left partially diagnosed.
Costs for maglock installation vary with door type, wiring complexity and whether fire alarm integration is needed. As a general reference point, standard lock installations in Ireland often run between €70 and €150, with more complex or high-security installations reaching €300 or more, and call-out or emergency rates adding to the total.
Maglock installations tend to sit above simple lock fitting because of the extra labour: running low-voltage cable, sizing and fitting a PSU and battery backup, and wiring REX and door contact devices all add time beyond mounting the lock itself. Where fire alarm integration is required, coordinating with a fire alarm contractor and arranging sign-off from a design professional adds further cost and scheduling complexity, since the electrical work and the compliance sign-off are usually separate visits.
Before hiring an installer, ask:
If the door sits on an escape route, insist on a site survey and a written compliance statement before work begins, rather than a verbal quote. A survey lets the installer confirm the correct bracket, PSU sizing and fire alarm interface for your specific door and building before any drilling starts, which avoids costly rework later.
Every maglock job throws up something the drawings did not show. Concealed steel frames behind a timber skin, door reveals a few millimetres off standard, or a previous installer’s redundant cabling left in the frame are all common, and they usually only show up once drilling starts.
Scheduling matters more than most people expect. When a job needs fire alarm integration, the mechanical fitting and the alarm contractor’s release wiring rarely happen on the same visit, and lining up both trades with the building manager’s availability is often the slowest part of the job, not the drilling.
Small costs tend to appear around the edges: a non-standard bracket for a glass door, an extra length of conduit for a concealed cable run, or a battery backup upgrade once the full accessory load is added up. None of these are large on their own, but they are worth budgeting for rather than treating as surprises.
A professional locksmith service can install and commission maglock systems on residential and commercial doors, often offering 24/7 availability for callouts outside normal hours.
— Barry
If the escape-route rules, wiring and commissioning steps above feel like more than you want to take on yourself, that is exactly the job ECS Locksmiths handles day to day. A visit typically includes a site survey to confirm the right lock, bracket and power setup for your door, a written quote before any work starts, and a compliant installation finished with full commissioning and a handover record you can keep on file.

Booking starts with a free estimate, and ECS Locksmiths aims to respond quickly to both scheduled installation requests and urgent callouts. What you get on site is a locksmith working through the same mechanical and electrical checks covered above, mounting, wiring, testing and fire alarm coordination where needed, rather than a partial fit you have to finish yourself.
If you would rather have a professional handle the installation from survey to sign-off, request a quote from ECS Locksmiths and get a site visit booked in.
For readers who want to check the rules and technical specifications directly, these are the sources behind the compliance and mechanical detail above:
Costs vary with door type and wiring complexity, but standard lock installations in Ireland often run between €70 and €150, with more complex or high-security jobs reaching €300 or more. Maglock installations usually sit above this range because of the extra wiring, PSU and backup work involved, and fire alarm integration adds further labour.
Mount the maglock to the frame header using the manufacturer’s specified hole pattern, then fit the armature plate to the door with a rubber and metal washer sandwich so it can rock and self-align against the magnet face. Wire in a correctly sized power supply, battery backup, REX device and door contacts, then commission and test the full system before handover.
Yes, a maglock needs a continuous power supply to hold the door locked, since it draws power the entire time it is engaged rather than only during release. The power supply must be sized for the lock’s continuous voltage and current rating, and a battery backup is needed to maintain security during a mains outage.
Maglocks are fail-safe, meaning they unlock automatically if power is lost, which some property owners see as a security drawback compared with fail-secure locks. They also require more wiring and peripheral hardware, PSU, battery backup, REX and often fire alarm integration, than a mechanical lock, and any fault in that power-cut path can leave the door either stuck locked or unable to hold securely.
A green box is a manual emergency release fitted beside a maglock on an escape route, wired to cut power to the lock directly and independently of the access control system. Official guidance lists it as a required feature for maglocks used on escape-route doors, alongside fire alarm integration.
It’s more than just unlocking doors. Most locksmiths provide:
Emergency lockouts (home, car, business)
Lock repairs and replacements
Key cutting and rekeying
Security upgrades (e.g. anti-snap locks)
Car key replacement
In emergency situations, typical arrival times should be at your location within 20-30 minutes. There are always professional locksmiths on standby, ready to handle any lockout or security emergency, ensuring safety is never compromised.
Absolutely! Most locksmiths specialise in advanced high-security lock systems, including electronic locks, biometric security, smart locks, and keyless entry systems. The should be trained in the latest security technologies, ensuring that they can provide the highest level of protection for your home, office, or vehicle. Ask for a free expert consultation to help you choose the right security system for your needs.
Yes, all locksmiths should stand by the quality of there work and offer a 100% satisfaction guarantee. Most would by default offer a warranty on all services, ensuring that you receive the best craftsmanship and long-lasting results.
Yes, most locksmiths are trained to open cars.
Most locksmiths in Ireland offer 24/7 emergency callouts and typically arrive within 15–60 minutes, depending on your location and traffic. In Dublin, response times can be as fast as 10–30 minutes, especially for emergency lockouts.
Yes A professional locksmiths use non-destructive entry methods first. Drilling is usually a last resort, not the default approach.
If someone immediately suggests drilling without inspecting the lock, that’s a red flag.
Costs vary depending on the service, time of day, and complexity of the job. A standard lockout is usually cheaper than replacing a lock. Emergency or late-night services may cost more.
Prices vary, but here’s a realistic guide:
Standard callout/labour: €85–€95
Lockout service: from ~€85–€120+
Lock replacement: depends on parts + labour
Important: Always ask for a full quote upfront and if there is a call out fee. Some companies advertise low prices but increase costs after arriving.
Prices can vary quite a bit… call around for quotes!
Yes A professional locksmiths use non-destructive methods whenever possible. Damage usually only happens if the lock is faulty, high-security, or has already been tampered with.
Yes. In Ireland, all locksmiths must be licensed by the Private Security Authority (PSA).
If you’re hiring someone:
Ask for their PSA licence number
Avoid anyone who can’t prove credentials
By asking for the licence you avoid the scammers.

Providing Locksmith Services For More Than 30 Years in Dublin, lock outs, lock fitting, slam locks, car opening, commerical and domestic.
Home
About Us
Services
Testimonial
Faqs
Privacy Policy
Terms & Conditions